BATTERY REPLACEMENT

The UH110 transmitter is powered by a standard alkaline 9 Volt

Swing the door open and take note of the polarity marked inside

battery. It is important that you use ONLY ALKALINE OR showing the location of the positive (+) and negative (-) termi-
LITHIUM batteries for longest life. Standard zinc-carbon batter-

nals. Insert the battery and close the cover by pressing in and

ies marked “heavy duty” or “long-lasting” are not adequate. They

across, reversing the opening procedure outlined above. Note

will provide only about 5 minutes of operation. Similarly, nicad

that the battery door will NOT close if the battery is inserted

rechargeable batteries only give 1 hour of operation, and will also

incorrectly, since the terminals will hit a protective polarity bar-

run down quite abruptly. Alkaline batteries provide about 5 hours

rier.

of operation while lithium batteries will run the unit for about 12

Don’t force the battery door closed. If it is difficult to close, the

hours.

battery is in backwards.

To open the battery compartment, press outward on the cover
door in the direction of the arrow as shown in the drawing. Only
slight, sliding pressure is needed to open and close the battery
door.

SWING OPEN

RELEASE
DOOR

OBSERVE
POLARITY

Battery Compartment Action

TROUBLESHOOTING

Before going through the following chart, be sure that you have a good battery in the transmitter. It is important that you follow these
steps in the sequence listed.

SYMPTOM

POSSIBLE CAUSE

TRANSMITTER BATTERY LED OFF

1) Battery is inserted backwards.

2) Battery is dead.

NO TRANSMITTER MODULATION LEDs

1) Gain control turned all the way down.

2) Battery is in backwards. Check power LED.

3) Mic capsule is damaged or malfunctioning.

4) Mic cable damaged or mis-wired.

6