Master reset, Initial setup, Input setup – Lectrosonics SPN32i User Manual

Page 12: Matrix crosspoint setup

Advertising
background image

ASPEN Input Only Processors

LECTROSONICS, INC.

12

After selecting the mode and/or changing the passcode,

select SAVE with the rotary control and press the center

switch to save the settings.

A progress bar

will appear as the

settings are saved.

Press the LEFT (9:00 o’clock) button to return to the

previous screen.

Master Reset

Hold the LEFT and UP buttons in at power up to restore

factory default settings.

WARNING: Master Reset will remove all stored

settings, unlock the control panel and reset the

passcode to five center button presses.

Master Reset takes about 75 seconds to complete

while the center (white) LED on the front panel stays lit.

The display will then return to the Main Window and the

right (blue) LED will light up to indicate power ON and a

“ready” status.

Initial Setup

The processor requires a minimum setup before it will

pass signals:

• Input Gain Value
• Crosspoint Gain Value
• Output Gain Value

These three minimum settings can be made with the

LCD or software GUI.

Input Setup

Select [INP] on the Main Window.

Select Mic/Line Input Setup (Input Levels is a dymanic

display that shows bar graphs of activity).

Navigate to each cell and enter a value. For micro-

phones, 40 to 50 dB is a normal value. For line levels,

0 dB is a commonly used value. If phantom power is

needed, be sure to check the 48V cell for each micro-

phone using the rotary control.

Matrix Crosspoint Setup

Select [MAT] on the Main Window.

Scroll to the desired Crosspoint setting and select it.

The UP and DOWN buttons can also be used to scroll

the menu items.