Liquid Controls SP2900 User Manual
Page 10

SETTING
16 POINT
K-FACTOR
16 POINT
ONLY
APPEARS
ON UNITS
WITH
16 POINT
OPTION
PRESS
DISPLAY
MENU FLASHES TO DEV TYP
LOCKOUT
OUTCARD
ALG OUT
OUT FREQ
RELAY
16 POINT
(16 POINT SELECTED)
MINUTES
HOURS
TEST
SECONDS
(PRESS D TO GO TO MINUTES)
(PRESS AS DESIRED)
POINT 00 (ENTER POINT 00 TO GO TO RUN
MODE)
(SELECT POINT 1)
POINT 01 (KEY IN POINT DESIRED)
F ## (SHOWS FREQUENCY IN MEMORY)
F 0
(AS AN EXAMPLE)
F 100 (FREQUENCY FOR POINT 1 IS 100)
K ## (SHOWS K-FACTOR IN MEMORY)
K 0
(AS AN EXAMPLE)
100 (K-FACTOR FOR POINT 1 IS 100)
POINT 02 (ENTER POINT DATA AS DESIRED)
POINT 00 (ENTER POINT 00 TO EXIT SETUP)
LAST COUNT READING
D
D
D
D
D
D
D
ENT
D
D
D
ENT
1
ENT
CLR
1
0
0
ENT
CLR
1
0
0
ENT
CLR
ENT
NOTE: If TEST
is entered, point
data can be
entered exactly
as in selected
time entries.
However, when
the unit "runs"
in Test Mode
"K-factor is
always 1.
"Rate" (R)
displays
frequency
(inputs per
second).
Counter dis-
plays 1 count
per each input.
NOTE: "BAD
SEQ" will
appear if
frquencies are
not in ascend-
ing order with
point numbers.
After 2 sec-
onds, the first
point number
with error will
appear so data
can be viewed
and corrected.
8