Setup procedure – Liquid Controls SP2900 User Manual
Page 5

PRESS
DISPLAY
PRESET A
(FINAL PRESET)
THEN FLASHING PRESET #
0 FLASHES
1 2 3 4 PRESET FLASHES
(SAMPLE PRESET)
1 2 3 4 IS ENTERED
PRESET B
(PREWARN)
THEN FLASHING PRESET #
0 FLASHES
1 2 0 0 PRESET FLASHES
(SAMPLE PREWARN)
1 2 0 0 IS ENTERED
MENU FLASHES TO DEV TYP
RT
CNT
(RATE OR COUNT)
(SET UP COUNTER)
K FACTOR FLASHES; THEN SHOWS
CURRENT K-FACTOR
0 FLASHES
1 . 2 7 8 FLASHES
(PRESS D FOR DECIMAL POINT)
K FACTOR IS DIVIDER. IT CONVERTS INPUT TO ENGINEERING UNITS.
(K FACTOR ENTERED)
R0
SP
(RESET TO 0 "ADD" OR SET TO
PRESET "SUBTRACT")
OR
SELECTS R0 OR SP
SELECTION ENTERED
DEC LOC (DECIMAL LOCATION)
PRESS ANY NUMBER
DECIMAL POINT MOVES TO THAT POSITION
LAST COUNT READING
SETUP PROCEDURE
NOTE: Start here and finish to the end. If you make a mistake, press
ENT until you reach the beginning.
STEP
1
SETTING
PRESET A
A
CLR
2
3
4
1
ENT
STEP
2
SETTING
PRESET B
CLR
2
0
0
1
ENT
B
D
ENT
D
2
7
8
1
D
CLR
B
D
ENT
ENT
STEP
3
SETTING
THE
COUNTER
ENT
3