Liquid Controls SP2900 User Manual
Page 8

STEP
7
SETTING
RATE OR
COUNT FOR
ANALOG
OUTPUT
SKIP IF NOT
USED
D
D
D
D
ENT
D
ENT
CLR
PRESS
DISPLAY
MENU FLASHES TO DEV TYP
LOCKOUT
OUTCARD
ALG OUT
(ANALOG SETUP SELECTED)
ANLG RT (4-20mA OUTPUT FOR RATE)
(PRESS D TO TOGGLE
ANLG CT (4-20mA OUTPUT FOR COUNT)
BETWEEN SELECTIONS)
(ANLG RT OR ANLG CT SELECTED)
SET LOW FLASHES THEN CURRENT
LOW SETTING
0 FLASHES
1 2 5 . 5 FLASHES
(PRESS D FOR DECIMAL POINT)
AS AN EXAMPLE (IN THIS CASE 125.5 = 4mA)
(LOW SET AT 125.5)
SET HIGH FLASHES THEN CURRENT HIGH
SETTING
0 FLASHES
1 5 0 . 7 FLASHES
(PRESS D FOR DECIMAL POINT)
AS AN EXAMPLE (IN THIS CASE 150.7 = 20 mA)
(HIGH SET AT 150.7)
LAST COUNT READING
MENU FLASHES TO DEV TYP
LOCKOUT
OUTCARD
ALG OUT
OUT FREQ
(OUT FREQUENCY SELECTED)
2000
(DISPLAYS LAST SELECTION)
200
10
20000
(PRESS D TO GO TO 2000)
(PRESS AS DESIRED)
LAST COUNT READING
1
2
5
5
D
ENT
CLR
1
5
0
7
D
ENT
STEP
8
SETTING
OUTPUT
PULSE
FREQUENCY
D
D
D
D
D
ENT
D
D
D
ENT
6