Liquid Controls SP3850 User Manual
Page 34

SP3850 Flow Computer
30
6.3.10
SETUP AUX 2 INPUT
NOTE:
When Density (Dens)
is selected, The menu
prompts will be very
similar to thePressure
prompts.
The menus will
prompt the user for
density values and
density units.
SETUP AUX2 INPUT
AUX 2 INPUT TYPE
None Dens
Press
AUX 2 SIGNAL TYPE
Voltage Current
CURRENT RANGE
4-20mA 0-20mA
AUX LOW SCALE
###### PSIA
AUX FULL SCALE
###### PSIA
AUX LOW ALARM
###### PSIA
AUX HIGH ALARM
###### PSIA
DENS EXTRACT METHOD
Therm_Coef API_2540
Advance To
SET FLUID PROPERTIES
ENTER
ENTER
ENTER
ENTER
Press ENTER to begin setup of the Auxiliary
Input 2.
Select Pressure to set the Auxiliary Input 2 for
Pressure inputs.
Choose Pressure Signal Type.
If Current selected,
Choose desired Current Range.
Enter the low pressure scale corresponding to
the low pressure signal.
Enter the high pressure scale corresponding
to the high pressure signal.
Enter the Low setpoint for the Pressure Alarm.
Enter the High setpoint for the Pressure
Alarm.
If None or Press selected, Choose the Density
Extraction method to be used.*
ENTER
ENTER
ENTER
ENTER
Sub-menus
Display
Notes
ENTER
* If not Density transmitter and not RTD.