UltraBond 10:1 Operations Manual

Rev. 12/2012

Page | 26

3.

Move the ram up/down valve handle to the up position (see figure 26).






Fig. 26








NOTE:

Do not install static mixer tube to gun at this time.


4.

To raise the Activator Ram, slowly increase air pressure on the regulator (marked air lift) to 15 to 20
psi (see figure 26).


5.

While the barrel piston is going up, check that hoses are moving freely and no hoses are kinking.


6.

Slide 5-gallon (20 liter) pail of activator onto the unit and center pail to the barrel piston.


7.

Open the air bleed ball valve located at the top of the barrel piston; this will allow air trapped
between the barrel piston and the activator to escape.







Fig. 27







8.

To lower barrel piston down into the pail, move the ram up/down handle to down position (see fig. 28).

Fig. 28