Magnum Venus Plastech PATRIOT 1:1 ADHESIVE SYSTEM User Manual
Page 23

Patriot 1:1 Adhesive System Operations Manual
Rev. 09/2012
Page | 23
14.
Secure leaks, if any.
15.
Allow Pump to continue pumping until there is a steady air free flow of Adhesive and Activator.
16.
Close the gun trigger.
17.
Position outlet of the gun over a flush container
18.
Place the air purge / solvent selector to the air purge position then press the flush buttons, a
sudden purge of material from dispensing head is likely and could splash, so be cautious (see fig.
15)
19.
Allow air to flow for 3-4 seconds (see fig. 15)
20.
Place the air purge / solvent selector to the solvent position then press the flush buttons
21.
Press flush button to solvent purge for 3-4 seconds and again watch for splashing
22.
Repeat flush process several times as needed.
Solvent from the flush tank
Air Purge air supply
Flush/Air Purge Button
Air Purge / Solvent selector
Figure 15