1:1 Classic Pro Gun Manual

Rev. 05/2012

Page | 18

Release System Pressure

1.

Properly Flush and remove the mixer and nozzle from the front of the gun.


2.

Turn OFF air supply to pumping system (pump pressure to zero).

3.

Release fluid pressure from lines by holding the gun over an appropriate empty
container and pulling the trigger.

4.

Flush gun into appropriate container

5.

Turn OFF air supply to the solvent tank.

6.

Release any pressure in the flush tank by gently pulling upwards on the ring
attached to the pressure relief valve.

7.

Place an empty container under the ball valve located at the bottom of the filter
assembly.

8.

SLOWLY open the ball valve, you can leave the ball valve open or close it when
all the pressure has been released.