C

ONNECTING

T

HE

A

CCEL

3-S

TAGE

R

EV

-

LIMITER

TO AN

A

CCEL

I

GNITION

S

YSTEM

he A

CCEL

3-Stage Rev-limiter uses special signals to communicate with your ignition

module, and your 3-Stage Rev-limiter can only be used with an A

CCEL

ignition module.

or your rev-limiter to communicate with your ignition module

DIP

-

S

witch-4, inside the

gnition module, must be re-set

UP

.

• Open the ignition module’s cover plate (the one with the wires coming through it).

Unscrew the three screws and swivel it out of the way to reveal the

DIP

-

S

witches.

• Using a small tool (A pencil is good) gently push

DIP

-

S

witch-4 up.

Your A

CCEL

ignition system’s internal

DIP-Switches are harder to access

than your rev-limiter’s buttons.

Set the ignition box’s rev-limit to the

highest value you ever expect to reach.

Your rev-limiter cannot override the
ignition’s designated rev-limit.

DIP

-

S

witch-4

This A

CCEL

300+ ignition box has been

set to rev-limit an 8-cylinder
engine at 5,000

RPM

.

The owner has
installed an A

CCEL

3-Stage Rev-limiter,
and has also set

DIP

-

S

witch-4 up.

I

MPORTANT

P

OINTS TO

R

EMEMBER

he rev-limit set inside your A

CCEL

ignition module is the engine’s ultimate rev-limit.

o outside control module will ever be able to override it. When setting P

EAK

RPM

on your

-Stage Rev-limiter it is a good idea to set it a little lower than the ignition module’s limit.

his allows you to program your A

CCEL

3-Stage Rev-limiter for its highest performance,

hile using the A

CCEL

ignition module’s rev-limiter as a safety.

you remove your A

CCEL

3-Stage Rev-limiter. remember to re-set

DIP

-

S

witch-4 inside the

CCEL

ignition module’s

• When connected to any control module, the ignition module’s

DIP

-

S

witch-4 must be U

P

.

• When not connected to a control module the ignition will not start with

DIP

-

S

witch-4 U

P

• When you have adjusted

DIP

-

S

witch-4, close the cover plate and

retighten all three screws.