Safety devices – MAX GS865E User Manual

Page 12

Advertising
background image

12

3. SAFETY DEVICES

The tool is provided with the following safety devices in order to secure safety for pin driving work.

Mechanical Safety Device
This tool is equipped with a FULL SEQUENTIAL ACTUATION MECHANISM. This tool
will not discharge pins unless the Contact Arm and Trigger have been activated
simultaneously. The pins are not discharged by neither simply pulling the Trigger nor
applying the Contact Arm to the pins driving object. The pins are discharged only after
apply the Contact Arm to the object and pulling the Trigger.

Trigger

Contact Arm

CAUTION:

● Prior to using the tool, be sure to inspect it to see whether the safety devices function

properly. Do not use it if they do not function properly.
Prior to using the tool, check whether the safety devices function properly. With no pins
loaded, install the Battery and Fuel Cell to check.

※ In the following cases, the safety devices are out of order. Never use the tool.

1. An operating sound is emitted by simply pulling the trigger.
2. The tool starts dry-fire operation by simply applying the contact arm to the object.

※ A fan running sound is heard, but this is not a fault.

If any abnormality is found, contact your nearest MAX authorized distributor for
inspection/repairing.

WARNING:

● To avoid accidental firing or double firing, pull the trigger rapidly and firmly.