Alliance Laundry Systems CHM160C User Manual

Page 23

Advertising
background image

Maintenance

21

F232172

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Figure 17

2. For 80 pound capacity models only, lubricate

bearings and seals each month OR after every
200 hours of operation. Refer to Figure 17.

a. Use a premium-grade lithium-based #2

grease. Never mix two types of grease, such
as petroleum and silicone.

b. Pump the grease gun slowly, permitting only

the following number of strokes:

Bearing grease fitting, 2 strokes

Seal grease fitting, 1 stroke

NOTE: Do not pump the grease gun until grease
comes out of the bearing housing. This can result in
overlubrication, causing damage to bearings and
seals.

3. Remove back panel and check overflow hose and

drain hose for leaks.

4. Unlock the hinged lid and check the supply

dispenser hoses and hose connections.

5. Clean inlet hose filter screens:

a. Turn water off and allow valve to cool, if

necessary.

b. Unscrew inlet hose and remove filter screen.

c. Clean with soapy water and reinstall. Replace

if worn or damaged.

6. Tighten motor mounting bolt locknuts and

bearing bolt locknuts. Check to see that the pin is
in place.

H047I

1

Bearing Grease Fitting

2

Seal Grease Fitting

H047I

1

2

Advertising