Minuteman PORT A SCRUB 14 User Manual

Page 18

Advertising
background image

Service hours

Daily

every every

every

50

100

200

Maintenance work

Check connections, extension cable and plug for good condition,
replace defective cable

Empty and clean (rinse) soiled water tank

Check sealing strips at the squeegee for condition.

Check squeegee for collected foreign matters and clean if required

Check the floater for function

Check filter sieve of the fresh water tank and clean if required..

Check squeegee sealing strips for wearing and replace if required.

Check the brush for tight fit and wearing and replace if required. Clean brush casing
by Brush

Check the tank lid gasket and replace if required.

Check fresh water infeed to the brushes

Clean nozzle

Check suction motor from carbon dust and check carbon brushes for smooth
operation and wearing. Replace carbon brushes if required.

X

X
X
X
X
X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

Disconnect the mains plug before executing maintenance or repair work. After these works have
Finished, proceed to a safety check.