Maintenance procedures, Cleaning the unit’s filter – MotorVac TRANSTECH III User Manual
Page 16

[email protected] www.motorvac.com
14
Maintenance Procedures
The following maintenance procedures should be performed on a routine basis:
1. Carefully clean the exterior with a soft cloth to keep the cabinet looking new. Check the cabinet for
dents or impact markings, if found, inspect for damaged components.
2. Check all hoses and wires for cuts or frays.
3. Clean the unit’s filter screens after every 100 services or 6 months, which ever comes first.
Cleaning the Unit’s Filter
1. Disconnect power harness from power source.
2. Remove the eight Phillip head screws from the unit’s back panel. Unsnap the lamp from back panel and
set back panel aside.
3. Locate the bell shaped plastic filter housing, found at the top of each tank. A clear plastic ½” hose runs
from each filter housing to a pump.
NOTE: Clean one filter at a time.
4. Remove the lock clip from the bell shaped plastic filter. Hold the bottom half of the filter while rotating the
top half of the filter counter-clockwise until the four lock tabs clear. Then separate the two pieces by lift-
ing up the top half of the filter.
5. Use a fine pick or bent pin to pull screen away from the filter housing. Clean screen.
6. Assemble in reverse order. NOTE: Use caution not to pinch O-ring on reassembly
7. Enter initials, date, and a check mark in the appropriate boxes of the Maintenance Record section of this
user manual.