System Features and Functions
The front of the TRANSTECH III cabinet contains the control panel, the fluid fill neck for adding new transmis-
sion fluid and the fluid level windows.
Front View - Control Panel Features and Functions
New Feature: Whenever the TransTech is reset with fluid in the waste tank, the Empty Waste LED will flash.
Note: It is not necessary to empty the Waste Tank before performing an exchange. If beginning an ex-
change with fluid in the waste tank ensure that there is less fluid in the clean tank than the remaining capacity
of the waste tank. Failure to do so will result in Waste Tank overflowing!
[email protected] www.motorvac.com
3
A
B
G
H
I
C
D
J
E
F
A. Start / Resume
(Fluid Exchange)
Begins service - Starts exchanging new fluid for used fluid. NOTE: With DRAIN, FILL, and ENGINE START
light on, service is in progress.
B. Drain
Drains fluid from vehicle’s transmission. When performing filter change, an alarm will sound when the
transmission is empty.
C. Low Vehicle Fluid
lluminates when fluid from the vehicle in service is low or empty.
D. Complete
Illuminates when service is complete or the stop button has been pressed
E. Start Engine
Flashes when the vehicle’s engine needs to be started, Is on solid when the vehicle’s engine is running and
sufficient flow is seen from the transmission.
F. Stop Engine
Flashes when the vehicle’s engine needs to be stopped,
Is on solid when the vehicle’s engine is OFF.
G. Fill (Top Off)
Adds fluid to the transmission.
H. Low Clean Fluid
Illuminates when clean fluid in the unit’s clean tank is empty.
I. Stop
Stops alarm if alarm is sounding.
Pauses the service if alarm is not sounding. Press Change Fluid button to resume service.
J. Empty Waste
Empties used waste fluid from unit’s waste tank.