WARNING

!

HL3

Series

2.0

Installation • Wiring

Electric Shock
Field wiring to the tube heater must be connected and grounded in accordance with national,
state, provincial, local codes and to the guidelines in the Tube Heater General Manual and
Series Insert Manual. In the United States refer to the most current revisions to the ANSI/NFPA
70 Standard and in Canada refer to the most current revisions to the CSA C22.1 Part I Standard.

Wiring

Figure 2.1

Field Wiring Diagrams

A. Single Heater, No Relay (Single Thermostat).

B. Multiple Heaters with Relay Option (Single Thermostat).

NOTE: If optional yellow

control cord is installed then

the following wire colors apply:

24VAC Out = green

Low = white

High = black

1/4” spade terminals

required (as supplied)

HL3

Burner Box

Thermostat

24VAC

N

Low

High

To 120VAC
grounded outlet.

24V

120VAC Power (observe polarity)

NOTE: If optional yellow control cord is
installed then the following wire colors apply:
Neutral = green
Low = white
High = black

1/4” spade terminals

required (as supplied)

HL3

Burner Box

Additional wire needed for thermostats
that require constant power.

24VAC

N

Low

High

External Transformer

(field supplied)

Thermostat

To 120VAC grounded outlet.

To 120VAC grounded outlet.

To 120VAC grounded outlet.

N

HL3

Burner Box

HL3

Burner Box

24VAC

120VAC

When using a thermostat that requires constant power a common wire must
be run form the C terminal on the thermostat back to the transformer.