Manual operation modes – Diamond Products CB66DS User Manual

Page 30

Advertising
background image

H30 Operation Manual

Houston Street Technologies

10

6. Manual Operation Modes

MANUAL RAMP

When in MANUAL RAMP mode the engine will operate within a range of configurable low and high RPM

values, increasing and decreasing speed in one of two manners: 5 second linearly or exponentially.

When using 5 second linear ramp rate the engine speed will increase from the low RPM setting to the high RPM

setting in a 5 second interval when the UP button is held. Engine speed will decrease in the same manner when

the DOWN button is held.

When using exponential ramp rate the engine speed will rapidly increase from the low RPM setting to the high

RPM setting when the UP button is held. Engine speed will decrease in the same manner when the DOWN

button is held.

When operating the engine using either ramp rate, each individual press of the UP or DOWN button will

increase or decrease the engine speed by approximately 16 RPM.

To access the MANUAL RAMP SETUP screen:

1) Press ENTER while at the Operation Screen to access the Main Menu.

2) Use U/D buttons to highlight OPERATING MODE and press ENTER.

3) Use L/R buttons to change the Operating Mode to MANUAL RAMP.

4) Use U/D buttons to highlight MANUAL RAMP SETUP and press ENTER.

MANUAL STEP

When in MANUAL STEP mode the engine will operate within a range of low and high RPM values, increasing

and decreasing speed in set increments. A maximum of (10) steps can be used to quickly (or slowly) increase or

decrease engine speed with each press of the UP or DOWN button.

To access the MANUAL STEP SETUP screen:

1) Press ENTER while at the Operation Screen to access the Main Menu.

2) Use U/D buttons to highlight OPERATING MODE and press ENTER.

3) Use L/R buttons to change the Operating Mode to MANUAL STEP.

4) Use U/D buttons to highlight MANUAL STEP SETUP and press ENTER.

RPM

IDLE

MANUAL STEP

STEP 1

STEP 2

STEP 3

STEP 4

Advertising