H30 Operation Manual

Houston Street Technologies

14

9. Digital Inputs

Below is a list of settings for the (8) digital inputs currently available. Contact HST for additional input

settings.

DIGITAL INPUT SETTING CONTROLLER/ENGINE RESPONSE

DISPLAYED MESSAGE

FLOAT SWITCH HIGH

BEGINS AUTO STARTUP SEQUENCE

"HIGH FLOAT SWITCH"

FLOAT SWITCH LOW

BEGINS AUTO SHUTDOWN

SEQUENCE

"LOW FLOAT SWITCH"

HYDRAULIC OIL TEMP

SHUTS ENGINE DOWN

IMMEDIATELY

"HYDRAULIC OIL TEMP HIGH"

LOW COOLANT SWITCH

NONE, TEXT WARNING ONLY

"LOW COOLANT LEVEL"

LOW FUEL LEVEL

NONE, TEXT WARNING ONLY

"LOW FUEL LEVEL"

LOW OIL LEVEL

NONE, TEXT WARNING ONLY

"LOW OIL LEVEL"

COOLANT TEMP

DECREASES ENGINE SPEED TO IDLE

"HIGH COOLANT TEMP"

OIL PRESSURE

DECREASES ENGINE SPEED TO IDLE

"LOW OIL PRESSURE"

OIL TEMP

DECREASES ENGINE SPEED TO IDLE

"HIGH OIL TEMP"

THROTTLE UP

MIMICS CONTROLLER’S UP BUTTON "THROTTLE UP"

THROTTLE DOWN

MIMICS CONTROLLER’S

DOWN BUTTON

"THROTTLE DOWN"

AIR FILTER RESTRICTION NONE, TEXT WARNING ONLY

"AIR FILTER RESTRICTION"

FUEL FILTER RESTRICTION NONE, TEXT WARNING ONLY

"FUEL FILTER RESTRICTION"

REMOTE START

CRANKS ENGINE

"REMOTE START"

EMERGENCY STOP

SHUTS ENGINE DOWN

IMMEDIATELY

"EMERGENCY STOP"