Diamond Products FZ-3S User Manual

Page 30

Advertising
background image

6.4

End of machining

Turn off power unit and unplug mains

Relieve pressure from the hydraulic circuits

Clean wall saw system, e.g. by hosing it
down

Remove blade guard

Remove saw blade and keep screws sa-
fely or screw them back into holes

Disconnect hoses

Turn the locking ring

Hold the hose end in straight position

Push the coupling sleeve back

Remove the hose

Connect both ends of the hose package
in order to keep the couplings clean and
protect them from damage during trans-
port

Unscrew the guide grips completely

Remove the wall saw head

Remove the tracks

Thvt

Aa"T

Page 30

FZ_39903

Advertising