2 setting the backlight, 3 enabling the weighing units, Auto power off – Nova-Tech CQT Series User Manual

Page 12: Setting the backlight, Enabling the weighing units

Advertising
background image

5.2 

SETTING

 

THE

 

BACKLIGHT 

The  backlight  may  be  enabled  or  disabled  by  the  user.  If  the  backlight  is  disabled, 
the battery life will be greater. 

The following settings are available:

 

1 BL

Sets the backlight to operate automatically when a weight is 
placed on the balance or a key is pressed. 

2 BL

Sets the backlight to be on all the time. 

OFF BL

Sets the backlight to be off. 

 

1) To set this parameter turn the power off press and hold the [Tare] key then 

press the [on/off] key once, then release the [Tare]  key. 

2) The display will show the first function PWR    

3) Press the [Unit] key until  the display shows XX BL where XX is the last setting 

4) Press [Tare] key to select the settings as follows 1 BL  ‐ 2 BL – OFF BL  

5) Press the [Unit] key to confirm the setting 

6) To exit turn the balance off and back on again 

5.3 

ENABLING

 

THE

 

WEIGHING

 

UNITS 

You can enable and disable the weighing units available to the user when they press 
the [Unit] key as described in section 4.4 Weighing Units.    

1) To set this parameter turn the power off press and hold the [Tare] key then 

press the [on/off] key once, then release the [Tare]  key. 

2) The display will show the first function PWR    

3) Press  the  [Unit]  key  until  the  display  shows  you  XX g where  XX  is  the  last 

setting on or off. 

4) Press the [Tare] key to select on or oFF. 

5) Press the [Unit] key to move to the next weighing unit.  

6) Repeat steps 5 and 6 until you have set all of the weighing units.  

12 | 

P a g e  

 

 

 

 

 

 

© Adam Equipment Company 2008

 