Nova-Tech 4180-4181 TRACEABLE PRINTING HYGROMETER_THERMOMETER User Manual

Nova-Tech Equipment

Advertising
background image

SPECIFICATIONS

Display:

Triple 4 digit LCD.

Over Range Indication: OL - appears.

Low Battery Indicative:

shows up when tire

battery’s voltage below the

operating voltage.

Sampling Rate :

about 1 time per second

Power Requirement: 6pcs 1.5V size AAA alkaline

batteries or 9V AC Adaptor /

500mA minimum.

Battery Life:

Approx. 90 hours. (Interval

printing = 60 minutes, excluding

beeper). 160 hours (without

printing & beeper).

Printing Interval:

6 sec to 59 win 59 sec

Operating Temperature

and Humidity:

0 to 50°C (32 to 122°F) below

95% RH

Storage Temperature

and Humidity:

–10 to 60°C (14 to 140°F)

below 70% RH Dimensions

(Meter):

193 (L) x 74 (W) x 37(H) mm

(Probe):

160 (L) x 13(D) mm/1m cable

Weight:

Approx. 430g with batteries &

thermo-paper.

Accessories

Carrying case, Instruction

manual, Batteries, 2 Rolls of

thermo-paper, type K probe.

Printer:

Thermo-printing tape with 16

characters per line using 38mm

width plain thermo-paper.

Electrical Specifications
Humidity:

Range:

10%RH to 95%RH

Resolution:

0.1%RH

Temperature (T1):

Range:

–20 to 60°C (–4 to 140°F)

Resolution:

0.1°C / 0.1°F

Dew Point:

Range:

–44.0 to 58.5°C (–47.2 to 137.3°F)

NAmE OF PArTS ANd POSITION

LCD: Measured values, until, symbols, and decimal

1.

points are displayed.

(CIRCLE): Key for power on/off

2.

[C/F]: Key for exchanging temperature unit °C and °F.

3.

[PRINT]:

4.

Key for start printing current data. The format

as below:

LINE 1 20:12:01 02-21

LINE 2

58.9%RH

LINE 3 td

15.7°C

LINE 4 T1

24.3°C

LINE 5 T2

24.8°C

Line 1: printing time hour minute: second, month- day.

Line 2: printing humidity value.

Line 3: printing Dew point value.

Line 4: printing T1 temperature value.

Line 5: printing T2 temperature value (K-Type).

Press this button for 2 seconds, the printer will

enter interval printing status, and won’t stop

unless this button is pressed again or FEED

button is pressed.

DC 9V VAC adaptor input jack.

5.

[FEED] PAPER (Fig-2):

6.

Key for moving forward thermo-paper

one line.

Perform force stop printing, and skip any

printing data.

[DEW POINT]: Key for changing humidity in

7.

dew-point display.

[MAX/MIN]:

8.

Press this key one time to enter

maximum/minimum record mode, the

“REC” symbol is displayed.

Press this key to display the maximum

reading (“MAXREC” symbol displayed),

the minimum reading (“MINREC” symbol

displayed) in cycle.

Press this key 2 seconds to exit this mode.

[HOLD]: Key for holding the display reading and press

9.

again to exit.

10.

: Key for start/stop set-up parameters mode.

Parameters (in sequence):

ON/OFF

(interval printing enable or disable).

TIME INTV (printing interval ranging from

00m:06s to 59m:59s).

INTV►

(Interval printing start time ranging from

00h:00m to 23h:59m).

INTV

(Interval printing stop time ranging from

00h:00m to 23h:59m).

TIME

(Calendar setting year, month, day, hour,

minute).

11.

DOWN: Key for decreasing the value of

parameters.

12.

RIGHT: Key for moving to the desired next

parameter setting.

13.

UP: Key for increasing the value of

parameters setting.

14.

LEFT: Key for moving to the desired forward

parameter setting.

Way out for thermo-paper.

15.

Type K temperature probe jack.

16.

Battery cabinet and cover: 6pcs 1.5V size AAA

17.

alkaline batteries.

Humidity (including temperature) probe.

18.
LCd dISPLAY

Dew point measurement indicator.

1.

Preset interval printing function ON indicator.

2.

Low battery indicator.

3.

Printing indicator.

4.

Interval printing start time setting indicator.

5.

Interval printing stop time setting indicator.

6.

Calendar time indicator.

7.

Interval printing indicator.

8.

T1 measurement indicator.

9.

T1 measurement value (NTC).

10.

T2 measurement indicator.

11.

T2 measured value (Type-K).

12.

Temperature measurement units.

13.

Humidity measurement units.

14.

Recording indicator.

15.

Minimum measurement value indicator.

16.

Maximum measurement value indicator.

17.

Data hold indicator.

18.

Humidity and dew point temperature measured

19.

value

PrECAuTIONS ANd PrEPArATIONS FOr

mEASurEmENT

Before operating this instrument, please examine it

1.

to make sure no shipping damage occurs. Otherwise

notify your dealer.

Save all packing materials until you are sure that this

2.

unit can normally operate.

Be sure that batteries are correctly placed in the case

3.

or adaptive 9V Adaptor is in correct connection.

An unsecured battery cover will cause error

4.

measuring.

To avoid battery leakage problem, remove batteries if

5.

this meter will not be used for a long time.

Do not use or store this meter outside the operating/

6.

storage environment.

OPErATINg PrOCEdurE

This meter can be supplied with batteries or DC 9V

1.

AC Adaptor. If using batteries:
Remove the rear cover, and install batteries, pay

attention to the polarity of battery socket. If using 9V

Adaptor, make sure that it is in good connection to

the Adaptor socket of the meter. Choose the K-type

temperature probe for your application and insert it

into T2 the temperature probe socket. Insert Humid-

ity/Temperature (T1) probe into T1 the meter socket.

Press the

2.

button to power on the meter, the current

date and time will display about 3 seconds. If “---“ ap-

pears, it indicates no probe or the probe is broken.

T1 indicates room temperature, T2 indicates K-type

3.

thermocouple test value.

Printing date:

4.

Press [PRINT] one time to print one set date.

If need continuous printing, press and hold down

PRINT button, until LCD display “INTV” mark and

enter continuous interval printing mode, the printer will

print data as follows:

INTV

00:06

Interval printing time, minute : second

10:55:19 08-16

Printing time, hour:minute:second,

month:day

62.7

%RH

Humidity test value and unit.

td

19.8 °C Dew point and unit

T1

27.6 °C Room temperature test value and unit.

T2

26.5 °C K-type thermocouple test value

and unit.

10:55:25 08-16

62.7

%RH

td

19.8 °C

T1

27.6 °C

T2

26.5 °C

10:55:31 08-16

62.7

%RH

td

19.8 °C

T1

27.6 °C

T2

26.5 °C

10:55:37 08-16

62.8

%RH

td

19.8 °C

T1

27.6 °C

T2

26.5 °C

Press [PRINT] or [FEED] key to exit printing mode.

When the meter is powered on, if the printing function

setting is “ON”, and now time is interval printing start

time, the meter will enter to continuous interval print-

ing mode and start printing.

* Press (PRINT) or (FEED) key to exit printing mode.

* The interval printing function worked only when the

start printing time is earlier than the stop printing time,

and interval print time can not be longer than

24 hours.

Caution: Before printing, please check thermo-paper is

not clipped by thermo-paper cover, if anything interrupts

the printer, the mater will shut off the printer power, and

” symbol flickers.

SETTINg mOdE

Press “

” button to enter setting function, re-press this

button can select setting parameters in circle (printer

on or off, interval printing time, start printing time and

calendar setting). The modifier parameter will flicker until

Advertising