Installation 3.3 tubing connections – Nova-Tech LMI Roytronic Series A Metering Pump User Manual

Page 10

Advertising
background image

10

INSTALLATION

3.3

Tubing Connections

Use only LMI tubing.

DO NOT USE CLEAR VINYL TUBING ON THE DISCHARGE SIDE OF THE

PUMP. The pressure created by the pump can rupture vinyl tubing, which is only for
connection to the return line of the FastPrime

fitting.

Before installation, all tubing must be cut with a clean square end.

Valve and head connections from the factory are capped or plugged to retain pre-prime

water. Remove and discard these caps or plugs before connecting tubing.

DO NOT USE PLIERS OR PIPE WRENCH ON COUPLING NUTS OR FITTINGS.

To assemble tubing into the fittings:

1. Put coupling nut over tubing.

2. Press on Ferrule – Female about one inch (25 mm).

3. For

1

4

" or 6mm OD tubing cut tubing so that only

1

4

" to

3

8

" (5-10 mm) protrudes

from the Ferrule. For all other tubing push the tube to the bottom of the groove in the
Ferrule – Male.

4. Firmly hand tighten the coupling nut onto the fitting. Tightening with pliers may cause

the ferrules to break.

Replacement

Ferrules, and

Coupling Nuts

are available as

the following kit

numbers:

¼

” Tube – 77382

3

8

” Tube – 77383

½

” Tube – 77384

One kit is needed

for each end of

the tube.

Coupling Nut

Ferrule - Female

Fitting

Ferrule - Female

Ferrule - Male

3

8

"

T

ubing

1

4

"

Tubing

1

2

"

T

ubing