Nova-Tech LMI Roytronic Series A Metering Pump User Manual

Page 23

Advertising
background image

23

OPERATION

4.4.1.4 Calibrating the Analog Input Settings (for A8)

1. Press and hold the Power/Mode Selection Button for more than 5 seconds. This enters

the calibration mode. Pumping will stop while in calibration mode.

2. Turn the Speed Adjustment Knob completely clockwise P to enter the fast level analog

input state. The Pulse Indicator Light will flash 1 second green ¼ second yellow.

3. Apply the desired fast level analog signal and press the Power/Mode Selection Button

for less than 3 seconds. The Pulse Indicator Light will be green for 1 second before
resuming flashing to confirm storage of the setting.

4. Turn the Speed Adjustment Knob completely counter-clockwise Q to enter the slow

level analog input state. The Pulse Indicator Light will flash 1 second yellow ¼ second
green.

5. Apply the desired slow level analog signal and press the Power/Mode Selection Button

for less than 3 seconds. The Pulse Indicator Light will be yellow for 1 second before
resuming flashing to confirm storage of the setting.

6. To return the pump to the factory default settings turn the Speed Adjustment Knob

to 50%. The Pulse Indicator Light should flash 1 second green, 1 second yellow. Then
press the Power/Mode Selection Button.

7. To exit calibration mode press and hold the Power/Mode Selection Button for more

than 3 seconds.