AD-4405 Weighing Indicator

18.

18.

18.

18. Relay Output & Control Input (O

Relay Output & Control Input (O

Relay Output & Control Input (O

Relay Output & Control Input (OP

P

P

P-

-

-

-05)

05)

05)

05)

Replacing the RS-232C interface with this option, 3-relay outputs and 3-control inputs

can be used with the RS-232C interface of this option.

RS-232C functions and pin connections are the same as the RS-232C interface

described in “16. RS-232C Interface”.

The control inputs can control the indicator from an external terminal just like the front

panel key operations.

Set the external control functions at f13, f14 and f15 of the F-Functions.

When connecting each function pin to the common pin, the indicator makes the action.

Keep a signal width more than 100 ms for the On-time and Off-time.

ON(Make)

More than 100 ms More than 100 ms

OFF(Break)

The relays output the result of comparison.

Solid-state-relay

Maximum voltage

DC50V

Maximum current

DC100mA

Maximum resistance 8

9

Pin connections (DIN 8pin connector)

Function

Pin No. Signal name

Direction

Description

1

HI

Output

Relay output HI

6

OK

Output

Relay output OK

4

LO

Output

Relay output LO

Relay

output

8 COM(out) -

Relay

common

terminal

3

EXT1

Input

Control input 1 (f13)

5

EXT2

Input

Control input 2 (f14)

7

EXT3

Input

Control input 3 (f15)

Control

input

2

COM(in)

-

Control input common

Adaptable connector

JA-TCP0586 (of accessory)

Circuits

Circuits

Circuits

Circuits

HI

OK

LO

COM(out)

K

EXT3

EXT2

EXT1

+7 to 9V

680

9

680

9

680

9

COM
(in)

DIN connector

of OP-05

Control input

Relay output

18. Relay Output & Control Input (OP-05)