16 sntp commands set, 37 chapter3, Table 3.16: sntp commands set – Advantech EKI-7657C User Manual

Page 47

Advertising
background image

37 Chapter3

systemlog mode

[client|server|both]

G

Specified the log mode

switch(config)# systemlog mode both

show systemlog

E

Displays system log.

Switch>show systemlog

show systemlog

P

Show system log client & server
information

switch#show systemlog

no systemlog

G

Disable systemlog functon

switch(config)#no systemlog

smtp enable

G

Enable SMTP function

switch(config)#smtp enable

smtp serverip

[IP address]

G

Configure SMTP server IP

switch(config)#smtp serverip 192.168.1.5

smtp authentication

G

Enable SMTP authentication

switch(config)#smtp authentication

smtp account

[account]

G

Configure authentication account

switch(config)#smtp account User

smtp password

[password]

G

Configure authentication password

switch(config)#smtp password

smtp rcptemail

[Index] [Email address]

G

Configure Rcpt e-mail Address

switch(config)#smtp rcptemail 1

[email protected]

show smtp

P

Show the information of SMTP

switch#show smtp

no smtp

G

Disable SMTP function

switch(config)#no smtp

event device-cold-start
[Systemlog|SMTP|Both]

G

Set cold start event type

switch(config)#event device-cold-start both

event authentication-failure

[Systemlog|SMTP|Both]

G

Set Authentication failure event
type

switch(config)#event authentication-failure both

event ring-topology-change

[Systemlog|SMTP|Both]

G

Set X - ring topology changed
event type

switch(config)#event ring-topology-change both

event systemlog

[Link-UP|Link-Down|Both]

I

Set port event for system log

switch(config)#interface fastethernet 3
switch(config-if)#event systemlog both

event smtp

[Link-UP|Link-Down|Both]

I

Set port event for SMTP

switch(config)#interface fastethernet 3
switch(config-if)#event smtp both

show event

P

Show event selection

switch#show event

no event device-cold-start

G

Disable cold start event type

switch(config)#no event device-cold-start

no event authentication-failure

G

Disable Authentication failure
event type

switch(config)#no event authentication-failure

no event ring-topology-change

G

Disable X - ring topology changed
event type

switch(config)#no event ring-topology-change

no event systemlog

I

Disable port event for system log

switch(config)#interface fastethernet 3
switch(config-if)#no event systemlog

no event smpt

I

Disable port event for SMTP

switch(config)#interface fastethernet 3
switch(config-if)#no event smtp

show systemlog

P

Show system log client & server
information

switch#show systemlog


3.1.16

SNTP Commands Set

Table 3.16: SNTP Commands Set

Netstar Commands

Level

Description

Example

sntp enable

G

Enable SNTP function

switch(config)#sntp enable

sntp daylight

G

Enable daylight saving time, if
SNTP function is inactive, this
command can’t be applied.

switch(config)#sntp daylight

sntp daylight-period

[Start time] [End time]

G

Set period of daylight saving time,
if SNTP function is inactive, this
command can’t be applied.
Parameter format:
[yyyymmdd-hh:mm]

switch(config)# sntp daylight-period 20060101-
01:01 20060202-01-01

sntp daylight-offset

[Minute]

G

Set offset of daylight saving time, if
SNTP function is inactive, this
command can’t be applied.

switch(config)#sntp daylight-offset 3

sntp ip

[IP]

G

Set SNTP server IP, if SNTP
function is inactive, this command
can’t be applied.

switch(config)#sntp ip 192.169.1.1

sntp timezone

[Timezone]

G

Set timezone index, use “show
sntp timzezone” command to get
more information of index number

switch(config)#sntp timezone 22

show sntp

P

Show SNTP information

switch#show sntp