Introduction, Component identification, Theory – Poweramp VH SERIES HYDRAULIC 10.2011 User Manual

Page 10

Advertising
background image

8

4111-0002 — Sept 2010

Component Identification

A — Lip

B — Platform

C — Lip Cylinder(s)*

D — Powerpack (Motor/Pump/Reservoir)

E — Logic Block

F — Platform Cylinder(s)*

G — Main Frame

H — Lip Keepers (4 used)

I — Maintenance Prop

J —Toe Guard (2 used)

K —Raise Button

L —ARTD Switch (option)

The VH dock leveler uses hydraulic logic and

one-button operation for ease of use.

The dock leveler can be operated remotely using the

RAISE button (J) on the control panel .

Platform (B) is raised by pushing and holding the

RAISE button (K). This activates an electric motor (D)

which, in turn, drives a hydraulic pump. The hydraulic

pump forces oil into the platform cylinder(s) (F),

causing the platform to rise. Releasing the RAISE

button allows the platform to lower.

When the platform rises to the point where there is

1 — 3 in. (25.4 — 76.2 mm) of travel left in the

platform cylinder, a cable pulls the valve lever up.

When the cable force exceeds the force necessary

to shift the spool valve inside logic block (E), the

spool shifts, causing oil to be redirected to the lip

cylinder(s) (C). This causes the platform to stop rising

and lip (A) to extend. When the lip has fully extended,

the platform will continue to rise until it reaches the

full raised position.

THEORY

INTRODUCTION

K

L

E

A

B

C

F

G

D

H

I