Troubleshooting – Poweramp AP SERIES AIR POWERED 4.2009 User Manual

Page 31

Advertising
background image

29

4111-0009 — Oct 2007
Jan 2009

TROUBLESHOOTING

Symptom

Possible Cause

Solution

Platform does not rise.
Pump operates in
pressure relief mode.

Heavy object(s) on platform. Remove object(s) from platform.

NOTE:

For safety reasons, the dock leveler
is designed to lift only the platform’s
own weight.

Dock leveler binds.

Check for visible obstructions that could cause
binding. Remove obstructions. If no obstructions
found, call Poweramp Technical Services. See
inside back cover for phone number and address.

Platform rises slowly

Air bladder or connecting
ducts punctured

Check air bladder and ducting repair or replace as
needed

Damaged or restricted
ducting

Replace damaged ducting or remove restriction

Air intake clogged

Remove intake filter, clean or replace as needed

Dock leveler binding

Check for visible obstructions that could cause
binding. Remove obstructions. If no obstructions
found, call Poweramp Technical Services. See
inside back cover for phone number and address.

Advertising