ADJUSTMENTS

25

4111-0006 — July 2006

NOTE: Adjusting the tension of lift springs (D) usually

requires that the lip assist spring (C) also be
adjusted.

If the platform does not rise fully and/or lip does not
extend fully, the lift spring tension may be set too low.

If the platform cannot be walked down or is difficult to
walk down, the lift spring tension may be set too high.

3. After lift spring adjustment is completed, check

operation of the lip.

• If the lip folds before the platform can be

walked down, tension of lip assist spring (C)
may be set too low.

• If the lip does not fold fully or takes too long to

fold, tension of lip assist spring (C) may be set
too high.

4. Adjust lip assist spring tension as follows:

NOTE: Use two-turn increments when adjusting lip

assist spring (C). Check lip operation after
each adjustment. Repeat until proper
operation is obtained.

a. Loosen jam nut (A).

b. To increase spring tension, turn nut (B)

clockwise.

c. To decrease spring tension, turn nut (B)

counterclockwise.

d. Tighten jam nut.

5. Recheck operation of platform and lip. Readjust lift

spring tension and lip assist spring tension until
proper operation is obtained.

1. Raise the platform and engage the platform

maintenance prop. Lock the maintenance prop in
the service position using an appropriate locking
device.

2.

Adjust tension of lift springs (D) as follows:

NOTE: Use 1/2 turn increments when adjusting lift

spring bolt (E). Check platform operation
after each adjustment. Repeat until proper
operation is obtained.

• To increase lift spring tension, turn lift spring

bolt (E) clockwise.

• To decrease lift spring tension, turn lift spring

bolt (E) counterclockwise.

If the platform does not rise fully on its own, it may
be necessary to use an external lifting device. Use
a lifting device with the appropriate lifting capacity
to safely raise the platform. Make sure to engage
and lock the platform maintenance prop after
raising the platform. Failure to do this may result in
serious personal injury or death.

IMPORTANT

IMPORTANT

When using an external lifting device to raise the
platform, make sure hold-down mechanism (F) is
disengaged. Pull and hold platform release ring
during the lifting process to avoid shearing the
ratchet pawl and ratchet bar teeth.