PSA PIN388D/PIN388L Installer Manual User Manual

Page 14

Advertising
background image

PINKERTON Installer Manual

13

REVIEW



Previous Events (Miscellaneous)

While in REVIEW mode, pressing Key



displays:

Zone
Light Meaning
1

Siren has been turned on.

2

Strobe has been turned on.

3

Dialler has been triggered.

4

Dialler failed (reached max. attempts).

5 (Not

used)

6

Maximum code attempts activated.

7

Low battery has turned off siren (and strobe).

8 Answered

phone.

W

ALK

T

EST

Key



Selecting this operation whilst the alarm system is off will initiate walk-test mode. Walk-test can
only be performed by holders of user codes 0 to 7. Walk-test mode allows all Zones and the siren
and the strobe to be tested. Operation is as follows:

When walk-test mode is first entered, all 8 Zone lights will be off. The AC Fail light will show
whether AC is present or not. The Low Batt light will show whether the battery charging voltage
is adequate.

As Zones are triggered the siren will squawk and the relevant Zone light will turn on and remain
turned on. This allows a "one man" walk-test by walking through all Zones.

Pressing the



key turns off all Zone lights and allows the test to be repeated, if required.


S

IREN AND STROBE TEST

.

While in test mode:

Pressing the



key will turn on the siren.

Pressing the



key will turn on the strobe.

This enables you to check the individual operation of the siren and strobe. Pressing the



key

will turn off the siren and strobe.

Press the

key to exit walk-test.

Please Note:

If the siren and strobe are being tested in the Mode and activation of a zone
will deactivate their respective output.