Equipment dimensions, Power requirements, Reviewing the front panel design – ADTRAN TRACER 4206 Plan A User Manual

Page 26: Rssi monitoring interface, Front panel leds, Rssi monitoring interface front panel leds, Figure 1, Tracer 4206 front panel layout, Table 1, Tracer 4106/4206 front panel description

Advertising
background image

Section 3 Engineering Guidelines

TRACER 4106/4206 System Manual

26

© 2004 ADTRAN, Inc.

612804206L2-1A

1.

EQUIPMENT DIMENSIONS

The TRACER 4106/4206 unit is 17.12” W, 9.34” D, and 1.72” H and can be used in 19 or 23-inch rack-mount
configurations.

2.

POWER REQUIREMENTS

The TRACER 4106/4206 system has a maximum power consumption of 20 Watts and a maximum current draw of
0.95 Amp (at 21 VDC).

3.

REVIEWING THE FRONT PANEL DESIGN

The front panel contains an

RSSI

test point, a

GND

reference for use with the RSSI test point, and status LEDs to

provide visual information about the TRACER 4106/4206 system. Figure 1 identifies the various test points and the
LEDs on a TRACER 4206 front panel. The TRACER 4106 front panel layout is identical to the TRACER 4206
front panel.

Figure 1. TRACER 4206 Front Panel Layout

RSSI Monitoring Interface

The RSSI voltage is a function of the signal strength at the receiver and is used to measure the received signal
strength. RSSI varies from approximately 0 to 5 Volts DC (VDC). An RSSI Calibration sheet is shipped with the
system to provide the installer a cross-reference between actual received signal level (in dBm) and RSSI voltage.
This sheet is useful for verifying link budget calculations and ensuring proper equipment installation.

Front Panel LEDs

With the TRACER 4106/4206 powered-on, the front panel LEDs provide visual information about the status of the
TRACER 4106/4206 system. Table 1 provides a brief description of the front panel features, and Table 2 provides
detailed information about the LEDs.

Table 1. TRACER 4106/4206 Front Panel Description

Feature

Description

RSSI Interface

DC voltage indicating strength of the received signal

GND Interface

Ground reference for

RSSI

interface

Status LEDs

Status information about the system

ALARM

T1A T1B T1C T1D

TRACER 4206

Status LEDs

RSSI

GND

Advertising