Rs-232 connection (db-25) — terminal use, Table 1, Rear panel description – ADTRAN TRACER 4206 Plan A User Manual

Page 28: Table 2, Rs-232 connection pinout

Advertising
background image

Section 3 Engineering Guidelines

TRACER 4106/4206 System Manual

28

© 2004 ADTRAN, Inc.

612804206L2-1A

RS-232 Connection (DB-25) — Terminal Use

The

RS-232

connector provides a female DB-25 terminal connection (wired as a DCE interface), which is

used for terminal access to the TRACER 4106/4206 system. The

RS-232

port provides the following

functions:

Accepts EIA-232 input from a PC or terminal for controlling the TRACER 4106/4206 system

Operates at 9600 bps

Table 2 shows the pinout. Wiring diagrams for connecting to the

RS-232

connector (for various

applications) are provided following the pinout.

Table 1. Rear Panel Description

1

1

Detailed discussions (including pinouts) of rear panel components (where applicable) follow the table.

Name

Connector

Description

A

RS-232

DB-25 (female)

VT100 terminal (or PC with terminal emulation software)
connection

B

Test

1/4” bantam

Factory test connection

C

T1A - T1D

RJ-48C

T1 device connection

D

Alarm

Terminal block

External alarm monitoring system connection

E

DC Power

Terminal block

21-60 VDC power source connection

F

Fuse

N/A

2 A, 250 V, 2 inch slow-blo fuse

G

Antenna

N-Type

Antenna feedline cable connection

H

Ground Lug

N/A

Earth ground connection

Table 2. RS-232 Connection Pinout

PIN

NAME

DESCRIPTION

1, 7

GND

Ground

2

TX

Transmit

3

RX

Receive

4

RTS

Request To Send

5

CTS

Clear To Send

6

DSR

Data Set Ready (Modem Control Only)

8

CD

Carrier Detect

9-19

Unused

20

DTR

Data Terminal Ready (Modem Control Only)

21

Unused

22

RI

Ring Indicator

23-25

Unused

Advertising