Table 1, Receiver sensitivity for the tracer 4106/4206 – ADTRAN TRACER 4206 Plan A User Manual

Page 49

Advertising
background image

TRACER 4106/4206 System Manual

Section 5 User Interface Guide

612804206L2-1A

© 2004 ADTRAN, Inc.

49

Both ends of the TRACER link must be set to the same number of active T1 ports. The TRACER 4106/4206
comes factory programmed with

A

CTIVE

T1 P

ORTS

set to

4

X

T1

.

>TRACER S

YSTEM

O

PTIONS

> M

ODEM

C

ONTROL

Configures the modem control leads on the RS-232 port (terminal interface located on the rear panel of the
unit). Set

M

ODEM

C

ONTROL

to

E

NABLED

when connecting the unit to a modem (using a null modem adapter).

Setting

M

ODEM

C

ONTROL

to

D

ISABLED

prevents the TRACER 4106/4206 from monitoring DCD and enables

data to be sent to the VT100 continuously.

M

ODEM

C

ONTROL

must be set to

D

ISABLED

when the VT100

terminal is in use. The TRACER 4106/4206 comes factory programmed with

M

ODEM

C

ONTROL

set to

D

ISABLED

.

>TRACER S

YSTEM

O

PTIONS

> M

ODEM

C

ONNECTION

(L

OGOUT

)

Causes the TRACER 4106/4206 to de-assert Clear To Send (CTS) and DSR for a time greater than 20 msec.
This signals the modem to disconnect the analog connection. Hangup-On-DTR-Drop may need to be
explicitly enabled on some modems. If

P

ASSWORD

P

ROTECTION

is

E

NABLED

, this menu also causes the unit to

close the current session and return to the TRACER System Status menu page and wait for password input.

>TRACER S

YSTEM

O

PTIONS

> P

ASSWORD

E

NABLE

Configures password protection for the VT100 terminal interface. Password protection for the
TRACER 4106/4206 requires password input from the TRACER 4106/4206 System Status menu page when
connecting to the unit. When configured for password protection, the TRACER 4106/4206 closes any
terminal session that remains inactive for more than 10 minutes. The TRACER 4106/4206 comes factory
programmed with

P

ASSWORD

E

NABLE

set to

D

ISABLED

.

>TRACER S

YSTEM

O

PTIONS

> P

ASSWORD

Sets the password for password protection of the TRACER 4106/4206 VT100 terminal interface. Enter up to
8 alphanumeric characters. The system password is case sensitive.

Table 1. Receiver Sensitivity for the TRACER 4106/4206

Delivered

Bandwidth

Receiver Sensitivity

Active

T1 Ports

TRACER 4106

TRACER 4206

4xT1

-93 dBm

-90 dBm

A – D

2xT1

-96 dBm

-93 dBm

A, B

1xT1

-98 dBm

-95 dBm

A

When changing active T1 ports on installed links, change the remote end first. If the local
end is changed first, remote configuration capability is lost. In the event the local end is
changed first and the link is dropped, reset the local end to the previous setting to restore
the link.

Press <Ctrl+Z> three times from the terminal interface to disable

M

ODEM

C

ONTROL

when

the modem control leads are active.

The default password for the TRACER 4106/4206 is tracer.