This section explains how to create a RAID 1 volume when the LSI 1068
SAS controller board is installed.

To initialize the LSI Logic Config Utility:

1

Turn on the server and the monitor.

If the server is already turned on, close all open applications, then
restart the server.

2

During POST, press Ctrl-C on the SAS BIOS prompt.

To load the factory default RAID setting:

1

On the LSI Logic Config Utility, press Alt-N to display Global
Properties.

2

Select Restore Defaults, then press Enter.

3

Press Esc, then select Save changes then exit this menu.

4

Select SAS1068, then press Enter.

5

Select Advanced Adapter Properties, then press Enter.

6

Select Restore Defaults, then press Enter.

7

Press Esc twice, then select Save changes then exit this menu.

To create a RAID 1 volume with a hot spare disk:

1

On the LSI Logic Config Utility, click SAS1068, then press Enter.

2

Select RAID Properties, then press Enter.

3

Select Create IM Volume, then press Enter.

4

Move the cursor to the RAID Disk column.

5

Press the space bar to change the setting from No to Yes.

The Drive Status will be marked as Primary.

6

Move the cursor to another disk.

7

Press the space bar to change the setting from No to Yes.

The Drive Status will be marked as Secondary.