B. adjustments c. lubrication, B. adjustments, C. lubrication – American Dryer Corp. AD-758 User Manual

Page 10

Advertising
background image

6

90 DAYS

Remove lint from basket (tumbler), drive motors, and surrounding areas. Remove lint from gas valve burner
area with a dusting brush or vacuum cleaner attachment.

NOTE: To prevent damage, avoid cleaning and/or touching the ignitor/flame-probe assembly.

Remove lint accumulation from inside control box and at rear area behind control box.

6 MONTHS

Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer’s internal
exhaust ducting.

WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK CAN

CREATE A POTENTIAL FIRE HAZARD.

WARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION

AIR. CHECK CUSTOMER FURNISHED BACK DRAFT DAMPER IN THE
EXHAUST DUCTWORK. INSPECT AND REMOVE ANY LINT
ACCUMULATION, WHICH CAN CAUSE THE DAMPER TO BIND OR STICK.

NOTE: A back draft damper that is sticking partially closed can result in slow drying and shut down of

the heat circuit safety switches or thermostats.

NOTE: When cleaning dryer cabinet(s), avoid using harsh abrasives. A product intended for the

cleaning of appliances is recommended.

B. ADJUSTMENTS

7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER

Inspect bolts, nuts, screws, (bearing setscrews), grounding connections, and nonpermanent gas connections
(unions, shutoff valves, and orifices). Motor and drive belts should be examined. Cracked or seriously frayed
belts should be replaced. Tighten loose V-belts when necessary. Complete operational check of controls and
valves. Complete operational check of ALL safety devices (door switches, lint drawer switch, sail switch,
burner, and hi-limit thermostats).

C. LUBRICATION

The motor bearings, idler bearings...and under normal/most conditions the basket (tumbler) bearings are permanently
lubricated. It is physically possible to re-lubricate the basket (tumbler) bearings if you choose to do so even
though this practice is not necessary. Use Shell Alvania #2 or its equivalent. The basket (tumbler) bearings used
in the dryer DO NOT have a grease fitting. Provisions are made in the bearing housing for the addition of a
grease fitting which can be obtained elsewhere.

The impellor (fan) shaft bearings should be lubricated every 3 months.