American Dryer Corp. AD-758 User Manual

Page 25

Advertising
background image

21

To Convert from Natural Gas to Liquid Propane (L.P.) Gas

NOTE: ALL dryers are sold as natural gas, unless otherwise specified at the time the dryer order was

placed. For L.P. gas the dryer must be converted as follows.

1. Refer to “Replace Gas Valve” and follow steps 1 through 6.

2. Remove the four (4) screws which secure the top cap assembly. This assembly contains the regulator

adjustment screw and the terminal connections.

3. Replace the top cap assembly with the L.P. version.

4. Unscrew main burner orifices and replace with L.P. orifices.

NOTE: Use extreme care when removing and replacing orifices. These orifices are made of brass and

are easily damaged.

5. Reverse the procedure for reinstalling valve assembly to the dryer.

WARNING: Test ALL connections for leaks by brushing on a soapy water solution. NEVER TEST

FOR LEAKS WITH A FLAME.

NOTE: There is no regulator provided in an L.P. dryer. The L.P. gas pressure must be regulated at

the source (L.P. tank) or an external regulator must be added to each dryer.

To Replace Burner Tubes

1. Refer to “Replace Gas Valve” and follow steps

1 through 6.

2. Remove four (4) screws securing manifold rest

and remove rest.

3. Remove the screws securing the front flanges

of the burner tubes to the burner tube rest.

4. Remove the screws securing the burner tube

rest to the oven and remove this rest.

5. Remove screws securing the sight hole disk and burner box cover plate to the oven and remove both of

these pieces.

6. Remove burner tubes by sliding them out.

7. Replace by reversing procedure.

WARNING: Test ALL connections for leaks by brushing on a soapy water solution. NEVER TEST

FOR LEAKS WITH A FLAME.

Advertising