L.E.D. DISPLAY CODES

A

Slope Factor

AUtO

Automatic Mode (Patent No. 4,827,627)

ArEv

Always Reverse

b

Heat Loss (offset) Factor

bUZ

Buzzer (tone)

bUZ–tinE

Buz Time

º CEL

Degree in Celsius

CL

Cool Down Cycle in Progress

COOL-tinE

Cool Down Time

COOL-tEnP

Cool Down Temperature

CY A

Preprogrammed Cycle A

CY b

Preprogrammed Cycle B

CY C

Preprogrammed Cycle C

CY d

Preprogrammed Cycle D

CY E

Preprogrammed Cycle E

CY F

Preprogrammed Cycle F

CYCL–tinE

Cycle Display Time

d

Dryness Level (percentage of extraction) (Numerical Value)

donE

Drying or Cooling Cycles Complete or Dryer is in Anti-Wrinkle Program

door

Door Circuit is Open or Fault in Door Switch Circuit

dr

Drying Cycle in Progress

drY–LEuL

Dryness Level (percentage of extraction)

drY-tEnP

Drying Temperature

dSFL

Dryer Sensor Circuit Failure

F

Fabric (temperature)

º FAr

Degree in Fahrenheit