KEYPAD FUNCTIONS (continued)

*Note: Use

"V-TEMP™ Keypad" illustration above to follow these instructions.

PARAMETER ACCESS AND ADJUSTMENT

The

V-TEMP

Electronic Control has many parameters the user

can adjust to customize the control.

To access the parameters:

a. Press and simultaneously hold the (5) “UP” button and (4)
“DOWN” button for 5 seconds. The first customizable parameter
will appear on the display.

b. To select a parameter to modify use the (5) “UP” button or (4)
“DOWN” button to navigate to the parameter you want to change.

c. Press the (6) “SET” button to go into modify mode.

d.

Use the (5) “UP” or (4) “DOWN” button to select the new

parameter value, then press the (6) “SET” button to lock in the
value.

e. You can now navigate to another parameter or you can exit
this procedure by pressing the (1) “ON” button for 1 second.
This will bring back the normal display.

"V-TEMP™ Keypad"

ALARM CODES, DESCRIPTIONS & RESOLUTION(S)

Code

Type of Alarm

AL

Minimum Temperature Alarm

RESOLUTION:
(a) Verify cabinet temperature
(b) Verify temperature associated with the alarm; see "A1" parameter

AH

Maximum Temperature Alarm

RESOLUTION:
(a) Verify cabinet temperature
(b) Verify temperature associated with the alarm; see "A4" parameter

id

Door Ajar Alarm

RESOLUTION:
(a) Make sure door is closed
(b) Verify operation of magnetic door switch

PF

Power Failure Alarm

RESOLUTION:
(a) Verify what caused the power failure. Press any button to stop alarm.
(b) Verify operation of magnetic door switch

COH

Condenser Overheat Alarm

RESOLUTION:
(a) Verify the condenser temperature. See "C6" parameter.
(b) Disconnect power and clean the condenser coil. Check for
obstructed air flow over condenser coil.

dFd

Compressor Overheat Safety Alarm

RESOLUTION:
This alarm activates when the defrost terminates on time rather than
temperature.
(a) Verify that the evaporator probe is intact and in the evaporator
coil.
(b) Press any button to restore normal display. The unit will continue
to function normally.

Once the cause that activated the alarm is resolved, the control
restores normal operation except for the following alarms that
require additional intervention:

1. "PF" (Power Failure Alarm): press any button to silence alarm

2. "CSd" (Compressor Overheat Safety Alarm): the cabinet
must be switched "OFF", or disconnect the main power supply

ERROR CODES

Code

Type of Alarm

Pr1

Cabinet Sensor Error

RESOLUTION:
The cabinet sensor is located in the return air stream in the evaporator
coil housing.
(a) Verify the integrity of the sensor.
(b) Verify the control sensor connection.

*Note: When this error occurs, the control will go into a safe mode.
The unit will operate in a pre-programmed ON/OFF cycle.

Pr2

Evaporator Sensor Error

RESOLUTION:
The evaporator sensor is located in the evaporator coil within the
evaporator coil housing.
(a) Verify the integrity of the sensor.
(b) Verify the control-sensor connection.

*Note: When this error occurs, the control will go into a safe mode.
The defrost will still activate, but operate on a 30 minute timer.

Pr3

Condenser Sensor Error

RESOLUTION:
The condenser sensor is located on the outlet tube of the condenser.
(a) Verify the integrity of the sensor.
(b) Verify the control-sensor connection.

*Note: When this error occurs, there will not be any "COH" or "Csd"
alarms.

rtc

Clock Error

RESOLUTION:
(a) The user must reset the date and time. See the section "SETTING
DATE AND TIME".

*Note: When this error occurs, the control has been without power
for over 48 hours.

Once the cause that activated the error is resolved, the control
restores normal operation except for the "rtc" error. This requires
the date and time to be set.

V-TEMP

V-TEMP

TM

TM

CONTROL ALARM & ERROR CODES