KEYPAD FUNCTIONS (continued)

*Note: Use

"V-TEMP™ Keypad" illustration above to follow these instructions.

SETTING DATE & TIME (*required for all ULTRASPEC™ units)
a.
Press the (4) “DOWN” button for a few seconds,“rtc” will appear
on the display.

b. Press the (6) “SET” button and “yy” for year will appear in the
display. Use the “UP” or “DOWN” button to get the correct year.

c. Hit the “SET” button to lock in the value and to take you to the
month value “nn”.

d. Use the “UP” or “DOWN” button to get the correct month and then
hit “SET” to lock in this value.

e. Keep on following the same procedure to set the day “dd”, hour
“hh”, and minute “nn”. *Note: The hour is based on a 24 hour
clock.

f. After the minute is set, the control will resume normal operation.

SETTING TEMPERATURE SETPOINT
a.
Press the (6) “SET” button and the compressor LED will flash and
display will show the current setpoint.

b. Press the (4) “DOWN” or (5) “UP” button within 15 seconds.

c. Press the (6) “SET” button to complete the procedure. The
Compressor LED will switch off.

*Note: Setpoint is the cut out temperature. A refrigerator has a 4˚F
differential; a freezer has a 5˚F differential. When a refrigerator is set
at 36˚F, it will cycle between 36˚F and 40˚F.

HACCP FUNCTIONS
The control can save up to 9 HACCP alarms after which the most
recent alarm will overwrite the oldest.

The control provides the following information:

> the critical value
> the date and time when the alarm was activated
> the alarm duration

CODE

TYPE OF ALARM

CRITICAL VALUE

AL

minimum temp alarm

minimum chamber temperature
during this alarm

AH

maximum temp alarm

maximum chamber temperature
during this alarm

id

door ajar alarm

maximum chamber temperature
during this alarm

PF

power failure alarm

chamber temperature when
power is restored

If the duration of the power failure alarm causes a clock error, the
control will not provide any information regarding the alarm duration.
The control has a 48 hour capacitor backup. Any power outage
longer than 48 hours may cause a clock error. If there is a clock
error, the time and date must be reset.

When the cause that activated the alarm event has been resolved,
the display restores normal operation except for the power failure
alarm. This requires the user to press a button to clear the alarm.

The HACCP LED provides information regarding the memory status
of the HACCP alarms. If it is on, not all of the information regarding
the HACCP alarms has been displayed. If it flashes, the instrument
will have saved at least one new HACCP alarm.

DISPLAYING INFORMATION REGARDING THE HACCP ALARMS
To access the information:

a. Press the (4) “DOWN” button for 2 seconds: the first label appears
on the display.

b. Use the (5) “UP” or (4) “DOWN” button to select “LS” (List)

c. Press and release the (6) “SET” button and either of the “AL”,
“AH”, “id”, or “PF” codes will appear on the display.

d. Use the (5) “UP” or (4) “DOWN” buttons to scroll through the
alarms and press the (6) “SET” button to display the information
pertaining to this alarm.

Note: If the control does not have any alarm saved, the “LS” label
will not be displayed.

The information regarding the alarm will appear on the display in
sequence. For example, the table below shows how the alarm will
be displayed for the "High Temp Alarm" 3

rd

occurrence.

INFO

MEANING

55

critical value is 55°F

StA

date and time when the alarm was activated is about to
appear on the display

y11

alarm was activated year 2011 (continues)

n03

alarm was activated during month of March (continues)

d26

alarm was activated on March 26, 2011

h16

alarm was activated at 16th hour (continues)

n30

alarm was activated at 16:30 hours (continues)

Dur

alarm duration is about to appear on the display

h01

alarm lasted 1 hour (continues)

n15

alarm lasted 1 hour and 15 minutes

AH3

selected alarm; meaning "High Temp Alarm" 3

rd

occurrence

To exit from the information sequence:

a. After the alarm goes through its sequence and the alarm is
displayed, AH3 in this example, press and release the (1) “ON/
STANDBY” button: “LS” will then be on the display.

b. Press and release the (1) “ON/STANDBY” button again to go back
to the normal display. If no buttons are pressed for 1 minute, the
control will also go back to the normal display.

DELETING THE LIST OF HACCP ALARMS
a.
Press and hold the (4) “DOWN” button for 1 second. The display
will show “rtc”.


b. Use the “DOWN” button to scroll and select “rLS”

c. Press and release the (6) “SET” button

d. Press the (5) “UP” button to scroll and select “149”

e. Press and release the (6) “SET” button. “- - - -“ will flash on the
display for a few seconds and the HACCP LED will go off and the
control will resume normal operation.