Remote switch connected to a primary cht channel – Electronics International TC-1P User Manual
Page 22
Channel #1
Channel #2
Channel #4
Channel #5
Channel #6
19
Remote Switch Connected to a Primary CHT Channel
This configuration allows a primary CHT instrument to monitor all the CHT's for a four or six
cylinder engine. This diagram shows cylinder #3 as the primary CHT. Your installation should
use the primary CHT cylinder for your aircraft.
"Wht/Violet and
Wht/Gray" Pair
Represents Two Connections.
RS-7-1P or RS-7-2P
Only
To Primary CHT
Cylinder #3
Primary Interconnect cable
supplied in the kit.
Single or Dual Display
Instrument
CHT
Channel
RS-5-2P and RS-7-2P Only
On the back of the RS-5-2P and RS-7-2P there are two groups of the above wires. When these switches are
used with one of Electronics International's Dual Display Instruments they can simultaneously select the
following:
1. Right and Left TIT and EGT's for a twin engine aircraft.
2. Right and Left CHT's for a twin engine aircraft.
3. TIT, EGT's and CHT's for a single engine aircraft.
Channel #3
Primary
Channel
"Brown" Pair
"Red Stripe" Pair
"Orange" Pair
"Yellow" Pair
"Green" Pair
"Blue" Pair
"Black" Pair