5 time – FEC AFC1200 User Manual

Page 17

Advertising
background image

)(& ,QF

For all control operations, the High and Low Torque Rate limits are set by determining the
acceptable limits from a study of known good and bad assemblies.

INTEGRATED TORQUE RATE

ANGLE

1st TORQUE / ANGLE

STD.

THRESHOLD 1 TORQUE

CROSSOVER RATE 2

2ND RATE HIGH

TORQUE RATE 1

TORQUE RATE 2

TORQUE RATE 3

1ST RATE

HIGH

2ND RATE

LOW

3RD RATE

HIGH

3RD RATE

LOW

1ST RATE LOW

TORQUE

3

3

1

1

2

2

FIG. 6-2-4b Integrated Torque Rate Method

FASTENING END

CROSSOVER RATE 2

3RD TORQUE RATE

CROSSOVER RATE 2

1st TORQUE/ANGLE

2ND TORQUE RATE

1st TORQUE/ANGLE

THRESHOLD 1

1ST TORQUE RATE

STOP POINT

START POINT

STAGE

6.2.5 Time

As outlined in the Fastening Control Methods portion of this Chapter, this System is capable
of performing multiple-step fastening operations. The duration of each of these steps is
governed by one of two independent watchdog time settings. If the step fails to attain the
desired result before the completion of the specified time, a reject condition will occur.

P

FINAL TIME

FASTENING END

3RD (TORQUE/ANGLE)

4TH STEP

FINAL TIME

3RD (TORQUE/ANGLE)

2ND (TORQUE/ANGLE)

3RD STEP

FINAL TIME

2ND (TORQUE/ANGLE)

1ST (TORQUE/ANGLE)

2ND STEP

1ST TIME

1ST TORQUE/ANGLE

START

1ST STEP

TIME PRESET

STOP POINT

START POINT

STEP

Chapter 6: Fastening Instructions

User Console Version A3.53

Page 6-17

Advertising