FINal torque speed to which the nutrunner will shift once 1st
TORQUE/ANGLE or SPEED CHANGE Torque is reached. SET based
upon the joint type to allow for a controlled final fastening. LESS THAN
50 RPMs.

TORQUE SPEED

FIRSt torque fastening speed. SET based upon the joint type to allow
for a controlled seating. LESS THAN 150 RPMs.

SLOWDOWN SPEED

Set based upon cycle time requirements. THIS speed is used to run
down the bolt quickly.

FREERUN SPEED

FOR joints that do not react properly to high speed seating, the freerun
time should be calculated to eliminate the "crash" effect.
[FREERUN TIME - INITIAL TIME = HIGH SPEED RUNDOWN TIME]

FREERUN TIME

SET to the rpm which will allow for easy socket to fastener
engagement.

INITIAL SPEED

SET to a duration which will provide sufficient time for the socket to
fastener engagement. MAy be set in either seconds or revolutions.

INITIAL TIME

SEt to the same value as the final torque speed. WHen the offset
check is enabled in the sequence program this speed will replace the
initial speed preset.

OFFSET CHECK SPEED

RECOMMENDATION

FUNCTION

SPEED

TORQUE

TIME

TIME

FREE RUN

SPEED

STD.

SPEED

CHANGE

SLOW

SPEED

TORQUE SPEED

OFFSET INITIAL SPEED

FIG. 6-3b Ideal Relationship of Speed and Torque