FEC AFC1200 User Manual
Page 21
Advertising

)(& ,QF
6.5
Torque Recovery
The Torque Recovery function is used when the potential for joint relaxation and interaction
exists. Under this control method, the fasteners are secured to final torque, and then held at
a programmed value for a programmed period of time. FEC INC. personnel have control of
the value and duration of the Torque Recovery function.
NOTE: This method of fastening must not be used without the assistance of FEC INC.
personnel. Attempting to utilize this method without assistance could result in
degraded System performance.
STD.
TORQUE
TIME
1
SEC.
FIG. 6-5 Torque Recovery
Chapter 6: Fastening Instructions
User Console Version A3.53
Page 6-21
Advertising