FEC AFC1100 User Manual

Page 13

Advertising
background image

)(& ,QF

9.9.7 code 8-6 servo amplifier error / source voltage abnormal

The controller internal power supply circuit is not working properly or the input voltage is
above the maximum limit.

This abnormal is caused from only 2 items.
1. The controller internal power supply has failed
2. Source voltage is very close to the limit (253 volts ac) and the environment temperature is
also close to the limit.

RECOVERY:
1. Replace the controller
2. Provide additional cooling to the enclosure.
3. Verify and correct the source voltage as required.

9.9.8 code 8-7 servo amplifier error / over load ( i square T)

The duty cycle of the fastening application is too severe for this size of tool, or for the
parameters currently setup.

RECOVERY:
1. Try to increase the amount of time allocated for fastening and slow down the fastening
speed of the tool.
2. If the problem remains, a larger tool assembly may be required for this application. Please
contact FEC.

Chapter 9: Troubleshooting (Rev. 8/98)

Page 9-13

Advertising