FEC AFC1100 User Manual

Page 14

Advertising
background image

)(& ,QF

9.10

Preset Error

9.10.1 code 9-0 preset error / reverse speed does not exist

The reverse speed preset is not setup or the wrong parameter number has been selected by
the PLC.

RECOVERY:
1. Verify that the parameter number that is being selected by the PLC is configured in the
controller.
2. Check that the reverse speed preset is not <0> or out of the specified speed range of the
tool

.

9.10.2 code 9-1 preset error / insufficient preset data

The fastening presets are not setup or the wrong parameter number has been selected by the
PLC.

RECOVERY:
1. Verify that the parameter number that is being selected by the PLC is configured in the
controller.
2. Check that the fastening presets are not <0> or out of the specified range for the tool.

9.10.3 code 9-2 preset error / system abnormal 1

The system controller experienced an internal processing error.

This abnormal is caused from only 2 items.
1. If the controller is located in an electric or magnetic noise field.
2. When the controller malfunctions.

RECOVERY:
1. Verify that the controller is not located near any high voltage transient power sources.
Relocate as required and reinitialize the system.
2. Exchange the controller with known working unit. Reinitialize the system after the
exchange

.

9.10.4 code 9-3 preset error / system abnormal 2

The system controller experienced an internal processing error.

This abnormal is caused from only 2 items.
1. If the controller is located in an electric or magnetic noise field.
2. When the controller malfunctions.

RECOVERY:
1. Verify that the controller is not located near any high voltage transient power sources.
Relocate as required and reinitialize the system.
2. Exchange the controller with known working unit. Reinitialize the system after the
exchange.

Chapter 9: Troubleshooting (Rev. 8/98)

Page 9-14

Advertising