FEC MICRO NR User Manual
Page 80

Chapter 7: System Operations
Page 7-12
「D-NO」 「PARM」 「DATA」
0 1 Calibration Torque (CAL value)
0 1 Peak Low Torque Limit
0 1 Peak High Torque Limit
0 8 Rundown Revolution Low Limit
0 8 Rundown Revolution High Limit
Last data of PARAMETER 8
FIG. 7-2-4b Parameter display D-No selection
When Parameter Display mode is enabled, the [D-No] display will show 2 digits (10-69)
representing the preset data number. The [DATA] display will show the corresponding preset data
value and the parameter display [PARM] will indicate the parameter number (from 0 ~ 8). Use the
[
] and [
] keys to change the preset data number [D-NO]. If the [D-NO] display is showing the
number 69 of the parameter number 1, pressing the [
] key will change the [D-NO] display to the
number 10 of the parameter number 2.
You can verify the fastening parameters by pressing the [
] and [
] keys at any time.
10
[
] [
]
keys
11
12
68
69
~