BTR TANK TYPE HEATERS
SERVICE HANDBOOK
A.O. Smith Water Products
Service Handbook
Irving, Texas ©2000
Training Department
25
GO TO PAGE 27 FOR DAMPER TESTS OF EFFIKAL EQUIPPED (SERIES 110, 111 AND
RETROFIT) MODELS
STEP 8
DAMPER INPUT TEST
STEP 8. DAMPER INPUT TEST. Test for 24 VAC between the yellow wire on the PC
board and ground. Effikal – Check from orange wire to neutral
IF
THEN
24 VAC is not present:
• Check the black wire connections
between the PC board and high limit.
24 VAC is present
• Go to step 6.
STEP 9
TEST THE DAMPER
STEP 9. TEST THE DAMPER. Visually check the damper blade position.
IF
THEN
The damper does NOT open fully:
• Replace the damper assembly
The damper DOES open fully:
• Go to step 10.
Test from
Orange
wire to
Black
(neutral)
Advertising