Fairbanks Aegis Industrial Mild Steel User Manual
Page 12

08/12
12
51102 Rev. 7
Section 3: Scale Installation
1. Select a location that is flat, solid, level, and one that fully supports the weight of
the platform plus a full capacity load.
2. Remove the top of the crate and all packing material.
3. Screw the
two (2) eyebolts
into the threaded adapters in the platform top.
4. Use a forklift or other lifting means, along with chains, cables, or nylon straps to
remove the scale from the crate bottom.
TWO TYPES of EYE BOLTS
Closed Gap Eyebolts
•
Open Gap Eyebolts (NOT USED)
•
Lifting Hooks (NOT USED)
5. Set the scale so that the interface cable exits in a direction where it can be
protected.
─
If possible, use a cable protector to reduce 'trip' hazards and to protect the
interface cable from being damaged.
C
A
U
T
I
O
N
DO NOT use hooks or unclosed eyebolts.
Failure to use proper lifting tools may result
in personal injury.