Fairbanks PC2250 Utility Software User Manual
Page 57

Appendix I: Data Output Formats
6/12
57
51214 Rev. 7
Condec Continuous Output
<STX><P><WWWWWWW><U><G><M><CR>
P = Polarity
space = positive weight
- = negative weight
W = Displayed weight
U = Units
L = pounds
K = kilograms
G = Gross; N = Net
M = Motion
Leading zeros are suppressed
Demand: Activated by the receipt of a <CR>.
Gross Weight – No Motion – decimal points included
<SP> <W> <W> <W> <W> <W> <W> <SP> <l> <b> <SP> <SP> <G> <R> <SP>
<SP> <CR> <LF> <EOT>
Gross Weight – Motion – decimal points included
<SP> <W> <W> <W> <W> <W> <W> <SP> <l> <b> <SP> <SP> <g> <r> <SP>
<SP> <CR> <LF> <EOT>
Net Weight – No Motion – decimal points included
<SP> <W> <W> <W> <W> <W> <W> <SP> <l> <b> <SP> <SP> <N> <T> <SP>
<SP> <CR> <LF> <EOT>
Net Weight – Motion – decimal points included
<SP> <W> <W> <W> <W> <W> <W> <SP> <l> <b> <SP> <SP> <n> <t> <SP>
<SP> <CR> <LF> <EOT>
Continuous: Outputs once every display update rate cycle.
Continuous Output formatted output. Same for Poll and Auto
Gross Weight – No Motion – decimal points included
<SP> <W> <W> <W> <W> <W> <W> <SP> <l> <b> <SP> <SP> <G> <R> <SP>
<SP> <CR> <LF> <EOT>