Main Product Features, Continued

• The PC2250 software utility program can also upload and modify the instruments

set-up, configuration, and calibration. Saved information can be downloaded from
a computer to the FB2250 Series in the event of a catastrophic failure.

• The instrument provides two (2) serial communication ports to provide

communication to various types of peripheral devices for RS232, RS422, RS485,
and 20mA data outputs.

• Optional accessories include a 4-20 mA analog output, Bluetooth® serial adapter,

and four different fieldbus devices; Profibus®, DeviceNet™, ControlNet and
Ethernet/IP.

Specifications

Instrument Approvals

• CC

09-023

• MC

AM-5720

• ETL

ETL Listed

• Conforms to ANSI/UL STD 60950-1
• Certified to CAN/CSA C22.2 STD NO. 60950-1-03

Specifications

• ENCLOSURE

ABS, Black NEMA 1, Stainless Steel NEMA 4X Desk
and Wall Mount

• DISPLAY

6 digits, 1 inch LCD, Green Backlight

• FRONT PANEL KEYS

On/Off, Units, Zero, B/G, Net, Tare and Print

• UNITS

lbs, oz, kg, g and lbs/oz, or custom

• GRADUATION SIZE

0.0001 to 50

• AD CONVERSION

66 per second

• LOAD CELL EXCITATION 5 Volts DC
• SENSITIVITY

1µv/d (microvolt/division)

• LOAD CELLS

Eight (8) 350 ohm or Sixteen (16) 1000 ohm

• DISPLAYED DIVISIONS

10,000d Commercial and 100,000d Non-Commercial

• CAPACITIES

Programmable to 999999