Fairbanks FB2255 Series Instrument PC2255 PC Software Utility Program User Manual
Page 42

Section 6: Fieldbus/Bluetooth
01/13
42
51297 Rev. 1
5.2.3.
CONTROLNET (
31979
), CONTINUED
NETWORK STATUS
MODULE STATUS
LED
STATE
INDICATION
A and B
OFF
Not online / No power
Flashing Red (1 Hz)
Incorrect node configuration, duplicate MAC ID etc.
Alternating Red/Green
Self test of bus controller
Red
Fatal event or faulty unit
A or B
OFF
Channel is disabled
Alternating Red/Green
Invalid link configuration
Flashing Green (1 Hz)
Temporary errors (node self-corrects) or node is not
configured to go online.
Green
Normal operation
Flashing Red (1 Hz)
Media fault or no other nodes on the Network
STATE
INDICATION
OFF
No power
GREEN
Operating in normal condition, controlled by a Scanner in RUN state.
FLASHING GREEN
(1 Hz)
The module has not been configured or the Scanner is in the Idle state.
Red
Unrecovrerable fault(s), EXCEPTION,
Flashing Red (1
Hz)
Media fault or no other nodes on the Network
No.
DESCRIPTION
1
Network Status LED A
2
Module Status LED
3
Network Status LED B
4
ControlNet Connector A
5
ControlNet Connector B